The axis moves and the motor vibrates, yet the CNC displays no alarm. This symptom deserves attention. An absent alarm does not automatically mean that the drive is operating correctly. Using the Okuma MIV04A-1-B5, reference 1006-2314, as an example, we e...
Not working: this Okuma MIV08DB-1-B5, reference 1006-2266, was repaired following damage to the power output stage and a failed cooling fan. The loss of cooling may have contributed to excessive thermal stress in the power section. The power stage was rep...
Yaskawa SGMG-13VSAAB: investigating a speed feedback fault
An alarm appearing as soon as a servo motor is connected may draw attention to its encoder. However, an alarm alone does not prove that the encoder is defective. Cables, connectors and the ...
Alarm A.41 although the Servopack switches on
The display is on, but the axis remains stopped. A Yaskawa SGDH-20DE-OY may report undervoltage even though the unit can be switched on. An active control circuit and a functioning power supply are separat...
A blown spindle-drive fuse can bring a CNC machine to a complete stop. Before restarting a FANUC A06B-6055-H212, establish whether the fuse has operated because of a fault in the drive or in the connected system. This documented workshop case illustrat...
On a Yaskawa SGMP-08AWMN31, feedback faults and mechanical wear can occur together. Project 123365 was reported with alarms A.81 and A.00. Inspection revealed worn bearings, an abnormal brake condition and a feedback-system fault. This article explains...
A servo motor can still run even when its bearings are worn. A Yaskawa SGMAH-02AAA61D-OY from our workshop illustrates this: incoming electrical measurements were acceptable and the motor ran, but the inspection also identified worn ball bearings. A s...
A clean motor housing tells you little about the condition inside. If coolant enters a servo motor, feedback, the brake and electrical insulation may be affected. This guide to the Mitsubishi HA-FF33B-EC explains how to narrow down these faults and when ...
The cooling fan on a Mitsubishi MDS-B-CVE-370 has stopped, yet the power supply still starts? Functional testing and condition assessment should then be considered separately. This guide explains the role of the Power Supply Unit, how to approach a stoppe...
A servo motor may run during initial inspection even though a fault was reported in the machine. This case from October 2022 shows why the customer report and workshop findings must be distinguished. The Yaskawa SGM-01U3AP01 arrived at industrypart from F...