Hello! I'm happy to help you with any questions about our service offerings.
Mitsubishi MDS-D-SP-200 nach der Reparatur und vor dem Versand, Schrägansicht.
11.10.2026 by Viktor Siebert
Mitsubishi MDS-D-SP-200 spindle drive: alarm 17 repaired

A Mitsubishi MDS-D-SP-200 spindle drive was sent to industrypart for repair with alarm 17. We reproduced the reported fault during incoming inspection. Further diagnosis identified a defect in the internal power supply. After repair and overhaul, the unit passed a test with a spindle at our test bench. The alarm did not recur during that test.

Nameplate data

ItemValue
ManufacturerMitsubishi Electric
ModelMDS-D-SP-200
Unit typeSpindle Drive Unit
Power marking18.5 kW [50% ED]
Main circuit input76 A; DC 270–311 V
Additional input0.2 A; 1PH 200/200–230 V; 50/60 Hz
Output63 A; 3PH 155 V; 0–833 Hz
Hardware versionR
Software marking1501W002 B0
Date marking11/07
Nameplate manual referenceIB-1500875

The ratings are transcribed from the supplied photograph. The 18.5 kW marking includes a 50% ED duty rating; it is not presented as a continuous output rating. The date marking is reproduced as printed.

Incoming inspection and workshop findings

The reported alarm could be reproduced during our incoming inspection. The subsequent examination identified a defect in the unit’s internal power supply. This specific finding provided the basis for the repair.

StageDocumented result
Incoming inspectionReported fault with alarm 17 confirmed
DiagnosisDefective internal power supply
Repair and overhaulFault corrected, unit thoroughly cleaned and wear-prone components renewed
Final testSuccessful test with a spindle; alarm did not recur

Alarm 17 and the internal power supply

The manufacturer’s alarm definition identifies the affected functional area. The internal power supply defect is the result of our examination of this particular unit. Alarm 17 alone therefore does not identify a specific failed component.

Electronic measurement and signal-processing circuits require a stable supply. An internal supply fault can also affect the processing of measurement signals, providing a possible technical link to current feedback. The affected supply rail and individual component are not documented for this report, so no more specific component-level cause is claimed.

Selected relevant alarms

Reference for MDS-D/DH servo and spindle drives. Only alarm 17 was reported in this repair case. The other entries provide context and are not additional findings.

CodeMeaning, paraphrasedCase relevanceManual page
17A/D conversion fault in current feedbackReported in this case6-13
32Power-module overcurrentGeneral reference6-5
33Main-circuit bus overvoltageGeneral reference6-5
3BPower-module overheatingGeneral reference6-5
4FControl power interruption of at least 50 msGeneral reference6-5

Source: Mitsubishi MDS-D/DH Series Instruction Manual, IB-1500025(ENG)-H, sections 6-2 and 6-3, pp. 6-5 and 6-13 (PDF pp. 426 and 434). The alarm reference is a different document from the specifications manual IB-1500875 printed on the nameplate.

Additional cross-check: the supplied extract “Alarme _ Troubleshooting-40.pdf”, pp. 6-4, 6-5 and 6-13 (file pages 2, 3 and 11), confirms the alarm meanings used here. The extract identifies the MDS-D/DH series but does not specify a separate revision.

Repair, cleaning and overhaul

We corrected the fault, thoroughly cleaned the spindle drive and overhauled it. Wear-prone components were also renewed. After completing the work, we tested the unit with a spindle at our test bench. The test was successful and alarm 17 did not recur.

Planning preventive maintenance

Professional condition assessment, cleaning and preventive overhaul can help identify developing ageing and wear. The scope and intervals depend on the condition of the unit, operating conditions and manufacturer instructions. The supply fault found here does not mean that every unit displaying alarm 17 requires the same component replacements.

Repair and test-bench work

The video explains the repair case and provides an insight into our test-bench work.

Before repair

Mitsubishi MDS-D-SP-200 before repair: front view.
Mitsubishi MDS-D-SP-200 before repair: front view.
Mitsubishi MDS-D-SP-200 before repair: angled view.
Mitsubishi MDS-D-SP-200 before repair: angled view.

After repair, before dispatch

Mitsubishi MDS-D-SP-200 after repair, before dispatch: angled view.
Mitsubishi MDS-D-SP-200 after repair, before dispatch: angled view.
Mitsubishi MDS-D-SP-200 after repair, before dispatch: front view.
Mitsubishi MDS-D-SP-200 after repair, before dispatch: front view.
Mitsubishi MDS-D-SP-200 nameplate with electrical ratings.
Mitsubishi MDS-D-SP-200 nameplate with electrical ratings.

Enquire about Mitsubishi spindle drive repair

Does your Mitsubishi spindle drive display an alarm? Send us the complete model designation, a nameplate photograph, the alarm indication and a description of when the fault occurs. industrypart supports you with diagnosis, repair and preventive overhaul of industrial drive electronics.

Mitsubishi MDS-D-SP-200 Spindle Drive Unit in our shop

For more information about our repairs of Mitsubishi servo and spindle drives, visit our Mitsubishi repair service page.

We are happy to assist you with any questions and inquiries.

Feel free to contact us anytime through our social media channels.

Get in touch with us

Mandatory fields are marked with (*)