27.11.2026 by Viktor Siebert
Mitsubishi MDS-B-SPX-300: Troubleshooting alarm A.32 on a TRAUB CNC
Does the TRAUB CNC report A.32 at power-up or only when the spindle is commanded to run? This observation helps maintenance teams narrow down the fault. An alarm before the drive is enabled calls for different checks from one that appears only under cutting load.
What does the MDS-B-SPX-300 do?
The Mitsubishi MDS-B-SPX-300 controls the spindle motor. The CNC sends the command, the drive supplies the motor, and the feedback system reports its actual motion. In the case documented here, the X-version drive was configured for a TRAUB machine with a hollow-shaft encoder. When selecting a replacement, check the full model designation, spindle motor, feedback system and machine parameter set together.
Technical data and machine configuration
| Item | Documented information |
|---|
| Manufacturer and model | Mitsubishi Electric MDS-B-SPX-300 |
| Device type and series | MDS-B series spindle drive |
| Workshop case configuration | TRAUB CNC with a hollow-shaft encoder |
| Cooling | Drive-mounted fan |
Fault reported in this repair case
The TRAUB CNC reported alarm A.32. We inspected the spindle drive in our workshop.
Workshop example: power output stage and cooling
During incoming inspection, we found a fault in the power output stage and a failed fan. We repaired the power output stage, renewed the cooling, cleaned the drive and carried out a preventive overhaul. Whether the failed fan contributed to the original fault remained undetermined.
Final test results
We used our own Mitsubishi control board and a test spindle for the final bench run.
| Checked on the Mitsubishi test bench | Documented result |
|---|
| Test spindle run | The repaired power electronics operated correctly. |
| Voltage and display | Both passed their checks. |
| Cooling fan | The fan operated correctly. |
The original control board in the customer-specific TRAUB configuration was outside the scope of this bench run. Recommissioning the machine requires checking its actual spindle and settings.
What to include in planned maintenance
Check cooling airflow and fan operation during planned maintenance. Back up the approved spindle parameter set alongside the full drive model designation. If the fault recurs, log the operating conditions in the maintenance record to see whether it clusters around startup, under load or after the machine warms up.
Technical sources and related article
Mitsubishi Electric – MDS-B-SPJ2, chapter 11 (code 32, related series) · Mitsubishi Electric – MELDAS 600M, section 3.12 (spindle parameters) · Workshop article on the MDS-B-CVE-370 power supply
Video from the Mitsubishi test bench
Photos before and after overhaul
Before repair
After overhaul on the Mitsubishi test bench
After overhaul – cooling fan side
Alarm A.32 and accompanying messages
| Message or indication | How it helps maintenance teams |
|---|
| A.32 on the TRAUB CNC | The alarm documented in this repair case. Refer to the alarm table for the specific TRAUB configuration. |
| Code 32 in the related MDS-B-SPJ2 series | Mitsubishi Electric lists this code in chapter 11 as power module overcurrent. |
| Further CNC, axis or power supply alarms | Record the affected unit and the order in the alarm history. This helps distinguish the first message from follow-on alarms. |
When the alarm occurs helps narrow down whether to focus on the drive, motor, motor cable or configuration.
Maintenance troubleshooting by when the alarm occurs
| When does A.32 occur? | What to record first | Where to start the technical checks |
|---|
| At power-up, before spindle enable | Save the first CNC alarm history entry and the drive display. Note any other axis or power supply alarms. | Identify which unit generated the alarm. If it appears without a spindle command, check the drive early in the process. |
| At enable or during startup | Record whether the motor starts to turn, whether the alarm occurs at no load and whether components were recently replaced. | Distinguish between the spindle drive, motor cable and motor. Following a replacement, verify the drive variant and the backed-up parameter set. |
| Only during acceleration, deceleration or cutting | Record the spindle speed, machining operation and spindle load, if displayed. | Compare the load and speed profile with earlier trouble-free runs. Use the result to guide checks on the motor, cable and drive. |
| Only after extended operation | Record how long the machine runs before the fault and note changes in fan noise or cabinet temperature. | Check fan operation and the cooling airflow during the next safe maintenance stop. Record any fan fault separately. |
For service, collect a photo of the full CNC alarm and the nameplate, the order in which messages appeared, the machine model and details of any recently replaced components. Save this information before clearing the alarm or removing the drive where possible. Electrical measurements and drive testing should be carried out by a qualified specialist.
Request a repair
Send us the full model designation, a photo of the alarm and when it occurred through our contact form. This helps us determine what to check for your spindle configuration.