30.04.2026 by Viktor Siebert
Fanuc A06B-6140-H026 aiPS Power Supply no function, no LED indication
Initial situation and error pattern.
The FANUC aiPS Power Supply A06B-6140-H026 was sent in with the fault “no function”. When powered on, the unit showed no reaction at all. No status LED, no display on the 7 segment indicator, no feedback from the system.
In the machine, this type of fault typically results in a complete standstill of all axes, since the power supply for the servo amplifiers is missing.
What was noticeable is that even the basic control electronics supply was not active. Normally, even in fault conditions, a power supply module remains in an alarm state. In this case, the unit was completely dead, which already pointed to an internal power supply failure.
Incoming inspection and initial diagnosis
During incoming inspection, the external supply was checked first. The mains voltage was present and correct. The input connections were mechanically and electrically in good condition.
Next, the internal power supply was tested. It quickly became clear that no stable internal voltage was being generated. The control electronics remained completely inactive.
At the same time, the power stage was roughly checked. Initial measurements showed abnormalities in the DC link area and in the power section. This indicated a combination of supply failure and age related wear.
Technical analysis
The aiPS module is the central energy supply for the entire servo system. It generates the DC link voltage for downstream amplifiers and supplies the internal control electronics.
In this case, the root cause was found in two areas:
First, a defect in the internal power supply. This unit is responsible for supplying the control boards. If it fails, the entire module becomes inactive. Typical causes are aged components due to long term thermal stress.
Second, the power stage showed clear signs of wear. Components in the DC link and power path were significantly aged. Such damage is often caused by:
long term thermal load
mains fluctuations
high load cycles
insufficient cooling
The combination of a weakened power supply and a stressed power stage ultimately led to total failure.
A note from the manual: a drop in control voltage or problems in the DC link can lead to module failure
Repair measures and refurbishment
The unit was completely disassembled. All assemblies were cleaned and visually inspected.
The following work was carried out:
repair of the internal power supply
replacement of critical components in the supply section
rework of the power stage
replacement of all known wear components in the DC link
preventive replacement of thermally stressed components
cleaning of the cooling system
The main focus was on preventive refurbishment. The goal was not only to restore functionality but also to avoid future failures.
Final functional test
After repair, the module was tested on the test bench.
Test procedure:
power on behavior checked
stable internal supply verified
DC link voltage monitored under load
test at low load
test at medium load
simulation of load changes
thermal stability checked
The unit showed clean startup behavior. The status display worked correctly. All voltages were within specification. Even under load, the system remained stable without abnormalities.
Conclusion
The failure was caused by a defective internal power supply combined with worn components in the power stage. The “completely dead” condition is typical for this combination.
Through full refurbishment including preventive measures, the module was sustainably repaired. Preventive maintenance is especially important for such units, as many failures develop gradually over time.
More details about our Fanuc repair services can be found here:
Fanuc drive Repair by Industrypart
📞 Feel free to contact us with any questions about your Fanuc drive technology.
Our expert team is happy to help!
Technical Specifications
| Parameter | Value |
|---|
| Manufacturer | FANUC |
| Device type | Power supply module |
| Model designation | A06B-6140-H026 |
| Series | aiPS |
| Power | approx. 29.8 kW |
| Input voltage | 200 to 240 V AC |
| Output voltage | 283 to 339 V DC |
| Rated current | approx. 106 A |
| Control type | Servo power supply |
| Feedback | none |
| Cooling | Fan cooled |
| Protection class | Control cabinet installation |
| Ambient temperature | 0 to 55 °C |
| Mounting | Cabinet mounting |
| Origin | Japan |
| Product status | Discontinued |
Operating environment and applications
Typical machines:
CNC machining centers
Turning machines
Automated production lines
Typical years of manufacture:
approx. 2005 to 2015
Typical applications:
Servo energy supply
DC link supply for axis drives
Requirements:
Stable mains supply
Good cabinet cooling
Low dust environment
Functional description
The aiPS module generates the central DC voltage for the servo axes.
It performs:
mains rectification
DC link generation
energy distribution to servo amplifiers
Additionally integrated:
overcurrent protection
undervoltage detection
overtemperature monitoring
In case of faults, the system shuts down to prevent consequential damage.
Alarm messages and troubleshooting
| Alarm code | Description | Possible cause | Recommended action |
|---|
| 1 | IPM fault | internal failure | check module |
| 2 | Control fan stopped | fan defective | check fan |
| 3 | Heatsink overtemperature | contamination | clean |
| 4 | DC voltage low | supply issue | check supply |
| 5 | Capacitor not charged | DC link fault | check |
| 6 | Control voltage low | PSU fault | repair |
| 7 | DC voltage high | regeneration issue | check |
| A | External fan fault | cooling failure | replace |
| E | Phase loss | supply issue | check input |
| H | Brake resistor overheated | load issue | check |
(Source: FANUC manual )
Assembly overview
| Assembly | Functional name | Function | Inspection / repair notes |
|---|
| Control board | A16B-2203-0630/08B | Control and monitoring of the power supply module | Check supply voltages, enable signals and connectors |
| Power board | A20B-2101-0390/06A | Power section, DC link and control of power components | Inspect for thermal damage and DC link faults |
| Power semiconductors | 3x A50L-0001-0342 / 2MBI200TC-060-01 | Switching and regulation in the main circuit | Check for short circuits and thermal damage |
| Internal fan | 109P0424H7D28 | Cooling of internal electronics | Check rotation, noise and airflow |
| Power section fan | 9WF1224H1D03 | Cooling of heatsink and power stage | Check function and contamination |
| Housing and heatsink | FANUC aiPS assembly | Mechanical structure and heat dissipation | Clean and inspect cooling surfaces |