Hello! I'm happy to help you with any questions about our service offerings.
Fanuc A06B-6140-H026 aiPS Power Supply Hauptbild
30.04.2026 by Viktor Siebert
Fanuc A06B-6140-H026 aiPS Power Supply no function, no LED indication

Initial situation and error pattern.

The FANUC aiPS Power Supply A06B-6140-H026 was sent in with the fault “no function”. When powered on, the unit showed no reaction at all. No status LED, no display on the 7 segment indicator, no feedback from the system.

In the machine, this type of fault typically results in a complete standstill of all axes, since the power supply for the servo amplifiers is missing.

What was noticeable is that even the basic control electronics supply was not active. Normally, even in fault conditions, a power supply module remains in an alarm state. In this case, the unit was completely dead, which already pointed to an internal power supply failure.


Incoming inspection and initial diagnosis

During incoming inspection, the external supply was checked first. The mains voltage was present and correct. The input connections were mechanically and electrically in good condition.

Next, the internal power supply was tested. It quickly became clear that no stable internal voltage was being generated. The control electronics remained completely inactive.

At the same time, the power stage was roughly checked. Initial measurements showed abnormalities in the DC link area and in the power section. This indicated a combination of supply failure and age related wear.


Technical analysis

The aiPS module is the central energy supply for the entire servo system. It generates the DC link voltage for downstream amplifiers and supplies the internal control electronics.

In this case, the root cause was found in two areas:

First, a defect in the internal power supply. This unit is responsible for supplying the control boards. If it fails, the entire module becomes inactive. Typical causes are aged components due to long term thermal stress.

Second, the power stage showed clear signs of wear. Components in the DC link and power path were significantly aged. Such damage is often caused by:

long term thermal load
mains fluctuations
high load cycles
insufficient cooling

The combination of a weakened power supply and a stressed power stage ultimately led to total failure.

A note from the manual: a drop in control voltage or problems in the DC link can lead to module failure


Repair measures and refurbishment

The unit was completely disassembled. All assemblies were cleaned and visually inspected.

The following work was carried out:

repair of the internal power supply
replacement of critical components in the supply section
rework of the power stage
replacement of all known wear components in the DC link
preventive replacement of thermally stressed components
cleaning of the cooling system

The main focus was on preventive refurbishment. The goal was not only to restore functionality but also to avoid future failures.


Final functional test

After repair, the module was tested on the test bench.

Test procedure:

power on behavior checked
stable internal supply verified
DC link voltage monitored under load
test at low load
test at medium load
simulation of load changes
thermal stability checked

The unit showed clean startup behavior. The status display worked correctly. All voltages were within specification. Even under load, the system remained stable without abnormalities.


Conclusion

The failure was caused by a defective internal power supply combined with worn components in the power stage. The “completely dead” condition is typical for this combination.

Through full refurbishment including preventive measures, the module was sustainably repaired. Preventive maintenance is especially important for such units, as many failures develop gradually over time.


To mentioned Fanuc Drive: Fanuc A06B-6140-H026 aiPS Power supply module

More details about our Fanuc repair services can be found here:
Fanuc drive Repair by Industrypart

📞 Feel free to contact us with any questions about your Fanuc drive technology.
Our expert team is happy to help!

Technical Specifications

ParameterValue
ManufacturerFANUC
Device typePower supply module
Model designationA06B-6140-H026
SeriesaiPS
Powerapprox. 29.8 kW
Input voltage200 to 240 V AC
Output voltage283 to 339 V DC
Rated currentapprox. 106 A
Control typeServo power supply
Feedbacknone
CoolingFan cooled
Protection classControl cabinet installation
Ambient temperature0 to 55 °C
MountingCabinet mounting
OriginJapan
Product statusDiscontinued

Operating environment and applications

Typical machines:
CNC machining centers
Turning machines
Automated production lines

Typical years of manufacture:
approx. 2005 to 2015

Typical applications:
Servo energy supply
DC link supply for axis drives

Requirements:
Stable mains supply
Good cabinet cooling
Low dust environment


Functional description

The aiPS module generates the central DC voltage for the servo axes.

It performs:
mains rectification
DC link generation
energy distribution to servo amplifiers

Additionally integrated:
overcurrent protection
undervoltage detection
overtemperature monitoring

In case of faults, the system shuts down to prevent consequential damage.


Alarm messages and troubleshooting

Alarm codeDescriptionPossible causeRecommended action
1IPM faultinternal failurecheck module
2Control fan stoppedfan defectivecheck fan
3Heatsink overtemperaturecontaminationclean
4DC voltage lowsupply issuecheck supply
5Capacitor not chargedDC link faultcheck
6Control voltage lowPSU faultrepair
7DC voltage highregeneration issuecheck
AExternal fan faultcooling failurereplace
EPhase losssupply issuecheck input
HBrake resistor overheatedload issuecheck

(Source: FANUC manual )


Assembly overview

AssemblyFunctional nameFunctionInspection / repair notes
Control boardA16B-2203-0630/08BControl and monitoring of the power supply moduleCheck supply voltages, enable signals and connectors
Power boardA20B-2101-0390/06APower section, DC link and control of power componentsInspect for thermal damage and DC link faults
Power semiconductors3x A50L-0001-0342 / 2MBI200TC-060-01Switching and regulation in the main circuitCheck for short circuits and thermal damage
Internal fan109P0424H7D28Cooling of internal electronicsCheck rotation, noise and airflow
Power section fan9WF1224H1D03Cooling of heatsink and power stageCheck function and contamination
Housing and heatsinkFANUC aiPS assemblyMechanical structure and heat dissipationClean and inspect cooling surfaces

We are happy to assist you with any questions and inquiries.

Feel free to contact us anytime through our social media channels.

Get in touch with us