18.11.2026 by Viktor Siebert
Fanuc A06B-6079-H207: Alarm 9 has disappeared permanently
Fanuc A06B-6079-H207: Alarm 9 has disappeared permanently
A machining company in Hamm, Germany, sent us a Fanuc A06B-6079-H207 servo amplifier for repair after alarm 9 appeared. Several months after the unit was returned, the customer confirmed that the machine was working as it should again.
Our customer’s feedback
“Alarm 9 has disappeared permanently, and the machine is working as it should again. Thank you very much for your service.”
Translated from the German feedback received on 12 November 2026. Thank you for your trust and kind words! We will gladly pass them on to our workshop colleagues.
Inspection and repair
The inspection revealed, among other findings, power modules fitted in the wrong positions. Our workshop repaired the circuitry and overhauled the servo amplifier. Electrolytic capacitors, including those on the control board, and optocouplers were replaced. Relay contacts were refurbished, and the fan was renewed. The existing power modules were installed in their correct positions.
Alarm 9 no longer appeared during the subsequent workshop test. The unit was returned to the customer on 19 May 2026. The November feedback now confirms successful operation in the machine.
Technical background
Our article on the repair of a Fanuc A06B-6079-H206 describes another repair involving alarm 9 on a related model. It provides technical background for a separate case and does not establish the cause in this A06B-6079-H207.
Project video and photos
Condition on arrival: overall view
Condition on arrival: front view
Original nameplate of the Fanuc A06B-6079-H207
Condition on arrival: connection area
Fanuc A06B-6079-H207 after repair