Okuma MPS60 / 1006-2204: alarm 1154-11 repaired

1154-11 ALARM-A MCS Power-Supply-Unit Error: An Okuma MPS60 power supply from the 1006-2204 family arrived at industrypart with this reported fault. Inspection identified defective load capacitors and damaged components in the power stage. The unit was heavily contaminated with oil and dirt, and one fan was barely turning.

Workshop findings: electronics and cooling

The reported alarm was the starting point for diagnosis. Inspection established which components were defective. Load capacitors and several power-stage components required replacement. Contamination and the barely turning fan were also recorded in the assessment.

The alarm text alone does not establish a single root cause. This report therefore focuses on the confirmed component defects and the condition of the unit.

Preventive overhaul based on repair experience

We replaced the defective parts and the components included in our preventive overhaul. Having repaired this model several times, we know its typical weak points.

Our preventive replacement includes both components that have reached their usual service life and additional parts that experience has shown to fail more frequently in this family. This work complements the repair of the immediate fault.

Extended testing on our test machine

After repair, the unit was tested for an extended period on our test machine. The video documents this test. The photographs show the condition before the work and views after overhaul.

Technical reference

ModelOkuma MPS60
Family1006-2204
Continuous capacity60 kW
System supply300 V DC / 24 V DC
TypePower regeneration

Okuma 4742-E, section 2, pp. 60 to 62.

Selected unit display codes

General reference, not additional faults observed in this case. The reported NC message 1154-11 must be distinguished from the local unit display.

01DC overvoltage
02DC undervoltage
09Power device fault
11Regeneration fault
13Heat sink overheating
1724 V control supply fault

Okuma 4742-E, section 2, p. 69.

Test after repair

Photographs

Okuma MPS60 1006-2204: After repair · front view
After repair · front view
Okuma MPS60 1006-2204: Nameplate · 1006-2204-025-023
Nameplate · 1006-2204-025-023
Okuma MPS60 1006-2204: Interior before repair
Interior before repair
Okuma MPS60 1006-2204: Before repair · view 1
Before repair · view 1
Okuma MPS60 1006-2204: Before repair · view 2
Before repair · view 2
Okuma MPS60 1006-2204: Before repair · view 3
Before repair · view 3
Okuma MPS60 1006-2204: After repair · view 1
After repair · view 1
Okuma MPS60 1006-2204: After repair · view 2
After repair · view 2
Okuma MPS60 1006-2204: After repair · view 3
After repair · view 3

Repair enquiry

Send us the complete model identification, a nameplate photo and the alarm message. We will assess your repair enquiry.

Okuma MPS60 / 1006-2204 · Okuma repair service

We are happy to assist you with any questions and inquiries.

Feel free to contact us anytime through our social media channels.

Get in touch with us

Mandatory fields are marked with (*)