21.11.2026 by Viktor Siebert
Okuma MIV05A-1-B5 (1006-2315) | Cooling fan failure, overhaul and CNC test
What cooling fan failure means on the Okuma MIV05A-1-B5
An Okuma MIV05A-1-B5 arrived at our workshop heavily contaminated. Its cooling fan had stopped, yet the servo drive passed the initial functional check on our CNC machine. The case shows why a short functional test and a cooling inspection answer different questions.
Drive identification and technical data
| Item | Details |
|---|
| Manufacturer and model | Okuma MIV05A-1-B5 |
|---|
| Part number shown on the tested unit | 1006-2315 |
|---|
| Family | MIV inverter unit in the Okuma Motion Control System (MCS) |
|---|
| Variant according to the model designation | A generation, ICB1, BL/PREX motor family, firmware type 5 |
|---|
| Continuous rating and dimensions | 4.8 kW, 380 × 60 × 295 mm (H × W × D), and 5.0 kg. These figures are for the MIV05A-1 in Okuma maintenance manual 4184-E. |
|---|
The MIV unit drives the motor. Depending on the machine configuration, the MCS also includes a separate MPS or MPR power supply, the servo link and encoder feedback. When investigating an axis problem, consider the entire drive system. Before replacing a unit, match the nameplate, machine model, motor assignment and controller ID against the relevant machine documentation.
Findings and preventive overhaul
- Incoming inspection. The drive was heavily contaminated and its fan did not run. The first functional check on the CNC showed no further functional fault.
- Overhaul. Once approved, we thoroughly cleaned the drive, replaced the failed fan and corrected the weaknesses found in the power supply.
- Final check. We retested the complete drive on our CNC machine and recorded a pass.
When we followed up, the service partner in Barcelona reported that the machine was running without any issues. See the customer feedback on the overhaul.
Diagnostics and MIV indications
The workshop record for this case contains no specific CNC or drive alarm. The following indications are from the Okuma maintenance manual and apply as diagnostic context for other cases.
| Indication | Diagnostic context |
EL or EH alternating with 13 | Inverter bridge error. For MIV01A-1 through MIV08A-1, manual 4184-E lists excessive heat sink temperature following external fan failure as a possible cause. A power-stage fault is also possible. |
|---|
AL / 05 | The fan appendix lists this indication for other sizes including MIV15A-1 and MIV22A-1. Use the alarm documentation for the actual machine to interpret the indication. |
|---|
| Encoder communication error | Record the full message and its additional data. Have maintenance staff assess the motor or encoder assignment and the feedback path using the machine documentation. |
|---|
For a repair enquiry, send a clear nameplate photo, the complete OSP alarm and supplementary code, the alternating characters on the MIV display and when the issue occurs. Details about cold starts, elapsed run time and operating load help narrow down temperature-related faults.
Testing and prevention
Inspect cabinet filters, airflow paths and cooling surfaces at the intervals in the maintenance schedule. Record the operating conditions when temperature issues recur. Follow the machine manufacturer’s instructions for work in the cabinet or on the DC link. This work belongs to qualified electrical personnel. The DC link can retain voltage after shutdown.
Sources
CNC test footage