Okuma MIV04A-1-B5 / 1006-2314: Drive alarm 03 and CNC alarm 1156 MCS
On the Okuma MIV04A-1-B5, A.L. and 03 flash alternately. The CNC displays 1156 MCS. Both indications point to DC bus voltage that was either too high or too low at the inverter. To narrow down the cause, note whether it happened at power-up, under load, or while decelerating.
Drive and alarm indications
| Item | Details |
|---|
| Manufacturer | Okuma |
|---|
| Drive | MIV04A-1-B5 |
|---|
| Reference | 1006-2314 |
|---|
| Assembly | MIV servo drive / inverter module |
|---|
| Drive display | A.L. and 03 flash alternately |
|---|
| CNC message | 1156 MCS |
|---|
What alarm 03 and 1156 MCS mean
The MIV module uses DC bus power to control the axis servomotor. Alarm 03 reports an abnormal voltage on that bus. The CNC reports the same fault condition as 1156 MCS and, depending on the control, can show the affected axis and a supplementary code. The full code helps identify the detected overvoltage or undervoltage value.
Troubleshooting by operating condition
| When it happens | What to record | Possible area to investigate |
|---|
| At power-up or drive enable | Timing, any preceding supply interruption and other CNC messages | Incoming supply and the MPS/MPR power supply alarm status |
|---|
| During movement or a load change | Axis, direction, feed rate and other affected axes | Supply under operating conditions and response of the MIV module |
|---|
| During deceleration | Braking sequence, load and any regeneration messages | DC bus and the power supply’s regeneration behaviour |
|---|
What the workshop checks
The workshop considers the MIV inverter alongside the common power supply. If several axes report an alarm at the same time, that helps evaluate whether the fault is in the common supply. If the alarm repeats on one axis, its drive can be investigated in more detail. The findings determine which unit needs repair.
Maintenance and information for a repair enquiry
If possible, photograph the full CNC message, its supplementary code, the affected axis and the sequence of alarms before resetting. Note what the machine was doing just before the shutdown. Report recurring faults early and follow the machine’s maintenance schedule. Electrical work on the DC bus should be carried out by qualified personnel.
Sources
Okuma MIV Inverter Unit, section 4-3-2, alarm 03.
https://www.mroelectric.com/static/app/product/pdfs/Okuma_MIV06_1_B5_Manual_2016218144653.pdf
Okuma OSP-U100M/U10M Alarm & Error List, Alarm A, 1156.
https://www.remontservo.ru/vanadzor/pages/publications/article-597/img-article/okuma-errors.pdf
Video guide
This video uses views of the drive to explain alarm 03, CNC alarm 1156 MCS and what to record before resetting.
Original photographs of the drive
Okuma MIV04A-1-B5 as received, showing the front connectors.
Nameplate showing model MIV04A-1-B5 and reference 1006-2314.
Enquire about an Okuma MIV04A-1-B5 repair
For a repair enquiry, send a nameplate photo, the complete CNC message and the operating conditions at the time of the alarm.
https://www.industrypart.com/products/okuma-miv04a-1-b5-or-1006-2314-servo-drive-42346.html