Okuma MIV04A-1-B5 / 1006-2314: Drive alarm 03 and CNC alarm 1156 MCS

On the Okuma MIV04A-1-B5, A.L. and 03 flash alternately. The CNC displays 1156 MCS. Both indications point to DC bus voltage that was either too high or too low at the inverter. To narrow down the cause, note whether it happened at power-up, under load, or while decelerating.

Drive and alarm indications

ItemDetails
ManufacturerOkuma
DriveMIV04A-1-B5
Reference1006-2314
AssemblyMIV servo drive / inverter module
Drive displayA.L. and 03 flash alternately
CNC message1156 MCS

What alarm 03 and 1156 MCS mean

The MIV module uses DC bus power to control the axis servomotor. Alarm 03 reports an abnormal voltage on that bus. The CNC reports the same fault condition as 1156 MCS and, depending on the control, can show the affected axis and a supplementary code. The full code helps identify the detected overvoltage or undervoltage value.

Troubleshooting by operating condition

When it happensWhat to recordPossible area to investigate
At power-up or drive enableTiming, any preceding supply interruption and other CNC messagesIncoming supply and the MPS/MPR power supply alarm status
During movement or a load changeAxis, direction, feed rate and other affected axesSupply under operating conditions and response of the MIV module
During decelerationBraking sequence, load and any regeneration messagesDC bus and the power supply’s regeneration behaviour

What the workshop checks

The workshop considers the MIV inverter alongside the common power supply. If several axes report an alarm at the same time, that helps evaluate whether the fault is in the common supply. If the alarm repeats on one axis, its drive can be investigated in more detail. The findings determine which unit needs repair.

Maintenance and information for a repair enquiry

If possible, photograph the full CNC message, its supplementary code, the affected axis and the sequence of alarms before resetting. Note what the machine was doing just before the shutdown. Report recurring faults early and follow the machine’s maintenance schedule. Electrical work on the DC bus should be carried out by qualified personnel.

Sources

Okuma MIV Inverter Unit, section 4-3-2, alarm 03.
https://www.mroelectric.com/static/app/product/pdfs/Okuma_MIV06_1_B5_Manual_2016218144653.pdf

Okuma OSP-U100M/U10M Alarm & Error List, Alarm A, 1156.
https://www.remontservo.ru/vanadzor/pages/publications/article-597/img-article/okuma-errors.pdf

Video guide

This video uses views of the drive to explain alarm 03, CNC alarm 1156 MCS and what to record before resetting.

Original photographs of the drive

Okuma MIV04A-1-B5 as received, showing the front connectors.
Okuma MIV04A-1-B5 as received, showing the front connectors.
Nameplate showing model MIV04A-1-B5 and reference 1006-2314.
Nameplate showing model MIV04A-1-B5 and reference 1006-2314.

Enquire about an Okuma MIV04A-1-B5 repair

For a repair enquiry, send a nameplate photo, the complete CNC message and the operating conditions at the time of the alarm.

https://www.industrypart.com/products/okuma-miv04a-1-b5-or-1006-2314-servo-drive-42346.html

We also offer service for similar articles


VAC5-D22 or U1233-0006 or VACV-D22 Spindle Drive Unit

5780.00 €

Buy

D11-B or 1006-1621 VACII-Drive Unit Type B

5740.00 €

Buy

e0241-680-014c Unit Type MSM